Loading...
Menu
Trending Products
Asus GL502VS GL502VS motherboard Asus GL502VS GL502VS motherboard
Asus GL502VS GL502VS motherboard
$302.00
Gigabyte GA-P67A-UD3R-B3 motherboard Gigabyte GA-P67A-UD3R-B3 motherboard
Gigabyte GA-P67A-UD3R-B3 motherboard
$105.40
Gigabyte GA-P67A-UD4 motherboard Gigabyte GA-P67A-UD4 motherboard
Gigabyte GA-P67A-UD4 motherboard
$84.30
Gigabyte GA-P41T-D3P Motherboard Gigabyte GA-P41T-D3P Motherboard
Gigabyte GA-P41T-D3P Motherboard
$38.00
Gigabyte GA-P67A-UD4-B3 motherboard
Gigabyte GA-P67A-UD4-B3 motherboard
$148.00

Phoenix PT 2X1- 5DC-ST 2856061 Surge protection plug

{{ product.price_format }}
{{ product.origin_price_format }}
Stock:
SKU:{{ product.sku }}
Model: {{ product.model }}
weight: {{ product.weight }} Kilogram

{{ variable.name }} : {{ variable.values[selectedVariantsIndex[variable_index]].name }}

{{ value.name }}

Quantity:

Specifications

Connection method Screw connection (in connection with the base element)
Screw thread M3
Tightening torque 0.8 Nm
Conductor cross section flexible 0.2 mm² … 2.5 mm²
Conductor cross section rigid 0.2 mm² … 4 mm²
Conductor cross section AWG 24 … 12
Color black (RAL 9005)
Copper color
Flammability rating according to UL 94 V-0
Housing material PA 6.6
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC 6 V DC
4 V AC
Rated current 300 mA (45 °C)
Operating effective current IC at UC ≤ 1 mA
Residual current IPE ≤ 1 µA (with PT 2X1+F-BE)
≤ 2 mA (Directly grounded)
Nominal discharge current In (8/20) µs (line-ground) 10 kA
Pulse discharge current Iimp (10/350) µs 2.5 kA (per path)
Total discharge current Itotal (8/20) µs 20 kA
Max. discharge current Imax (8/20) µs maximum (line-earth) 10 kA
Nominal pulse current Ian (10/1000) µs (line-earth) 125 A
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 14 V
≤ 600 V (with PT 2X1+F-BE)
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 10 V
Residual voltage at In (conductor-ground) ≤ 10 V
Residual voltage with Ian (10/1000) µs (line-earth) ≤ 12 V
Voltage protection level Up (line-earth) ≤ 50 V (C2 – 10 kV / 5 kA)
Response time tA (line-earth) ≤ 1 ns
Input attenuation aE, asym. 0.5 dB (≤ 200 kHz)
Cut-off frequency fg (3 dB), asym. (PE) in 50 Ω system typ. 1 MHz
Capacity (Core-Earth) 3 nF
Resistance per path 4.7 Ω (1-2/5-6/7-8/11-12)
Surge protection fault message none
Max. required back-up fuse 315 mA (T)
Impulse durability (line-earth) C2 – 10 kV / 5 kA